Femur Loc plates with Available Combined Multi Angle Hole

141o032-5 Cp',fa.

PERI-LOC Proximal Femur Locking Bone Plates, Bone Screws, Locking Hole Inserts and Cable Accessories are indicated for fractures of the trochanteric region including simple intertrochanteric, reverse oblique trochanteric, transverse trochanteric, complex multi-fragmentary, and fractures with medial cortex instability; proximal femur fractures

141o032-5 Cp',fa.

PERI-LOC Proximal Femur Locking Bone Plates, Bone Screws, Locking Hole Inserts and Cable Accessories are indicated for fractures of the trochanteric region including simple intertrochanteric, reverse oblique trochanteric, transverse trochanteric, complex multi-fragmentary, and fractures with medial cortex instability; proximal femur fractures 4.5 mm LCP Proximal Femur Plates TGFemur Plates and Proximal Femur Hook plates, complex fractures of the distal femur with the 4.5 mm LCP Condylar Plates, and complex fractures of the proximal tibia with the 4.5 mm LCP Proximal Tibia and LCP Medial Proximal Tibia Plates. The locking compression plate (LCP) has Combi holes in the plate shaft that combine a dynamic compression

51 0(k) Summary of Safety and Effectiveness

The subject implant devices will be available in the following configurations:Devices Available With the Device Type Following Number of Individual Locking Screw Holes Per Plate PERI-LOC 4.5mm Lateral Proximal Femur Locking Plate, LH 2, 4, 6,9,12,15 or 18 PERI-LOC 4.5mm Lateral Proximal Femur Locking Plate, RH 2, 4, 6, 9, 12, 15 or 18 A Practitioners Guide to Fracture Management, Part 3 Orthopedic Hardware:IM Pin & Cerclage Wire. IM pins and Kirschner wires (K-wires) are made from 316L stainless steel. The difference between pins and k-wires is mainly diameter:IM pinsalso referred to as Steinmann pinsare between 1.5 mm (1/16 inch) and 6.5 mm (1/4 inch) in diameter, while K-wires are 0.9 to 1.5 mm (0.035, 0.045, 0.062 inches) in diameter. 1

A Practitioners Guide to Fracture Management, Part 3

With locking plates, the screw heads thread into the plates, creating a locked fixed-angle system that behaves more like an ESF and does not require friction between the bone and plate. In addition, the axial force through the bone creates a compressive force at the screwbone interface. A regression orthogonal biomechanical analysis of internal Jul 01, 2020 · Firstly, a simplified model of transverse femoral shaft fracture is built, and varieties of geometric sizes for plates and screws configurations are combined based on orthogonal array. Next, the biomechanical indexes of different combinations are calculated through finite element analysis (FEA).

AcUMEDr - UW Faculty Web Server

plate placement has greater strength and stability,especially when the elbow is subjected to A/P and torsional forces3. Tap-Loc Technology allows the surgeon to angle the locking screws in the distal humerus up to 20° in each direction and create threads in the plate hole with a customized tap. This All Products - China Implant manufacturer, Stapler, Plate Surgical Instrument ium 5.0mm Proximal Lateral Tibial Golf Locking Plate with Available Combined or Multi-Angle Hole FOB Price:US $1 / Piece Min. Order:1 Piece

All Products - China Implant manufacturer, Stapler, Plate

ium Proximal Lateral Femoral Locking Plate I with Available Combined or Multi-Angle Hole Surgical Instrument ium 5.0mm Proximal Lateral Tibial Golf Locking Plate with Available Combined or Multi-Angle Hole FOB Price :US $1 ium Ts Distal Tibial Loc Plate (YAP) with Available Combined or Multi-Angle Hole Biomechanical Evaluation of Dual Plate Configurations for Apr 28, 2019 · A diaphyseal femoral midshaft fracture was simulated by performing a transverse osteotomy. The fracture was spanned and stabilized with either 10-hole 4.5 mm stainless steel dynamic dual compression plates (DCP) (DePuy Synthes Inc., West Chester, PA) or dual locking plates (DLP) (Smith & Nephew Inc., Memphis, TN).

Biomechanical Evaluation of Dual Plate Configurations for

Feb 26, 2019 · A diaphyseal femoral midshaft fracture was simulated by performing a transverse osteotomy. The fracture was spanned and stabilized with either 10-hole 4.5 mm stainless steel dynamic dual compression plates (DCP) (DePuy Synthes Inc., West Chester, PA) or dual locking plates (DLP) (Smith & Nephew Inc., Memphis, TN). Biomechanical analysis of plate systems for proximal Apr 27, 2018 · Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use.

China Implant manufacturer, Stapler, Plate supplier

ium S-Clavicle Locking Plate Plate II with Available Combined or Multi-Angle Hole FOB Price:US $1 / Piece. Surgical Instrument ium Clavicle Hook Loc Plate with Available Combined FOB Price:US $100 / Piece. ium Distal Lateral Femoral (condylar) Locking Plate with Available Combined or Multi-Angle Hole Femoral neck anteversion:Values, development, Jun 13, 2020 · 5, 7 If the axis of femoral neck is parallel to the transcondylar plane, the angle of torsion is zero, and it is known as neutral version. 5,7 Femur neck anteversion measurement is crucial for tic

Guideline for Bolted Joint Design and Analysis:Version 1

qi nd Ratio of the clearance hole diameter (dc) to the bolt diameter (db) Re L Effective radius to which the torque is applied (average of Ro and Ri. Ri L Analysts estimate of inner radius of the torqued element (often equal to db/2 if clearances are ignored) Ro L Analysts estimate of outer radius of the torqued element (often equal to dh/2) Guideline for Bolted Joint Design and Analysis:Version 1qi nd Ratio of the clearance hole diameter (dc) to the bolt diameter (db) Re L Effective radius to which the torque is applied (average of Ro and Ri. Ri L Analysts estimate of inner radius of the torqued element (often equal to db/2 if clearances are ignored) Ro L Analysts estimate of outer radius of the torqued element (often equal to dh/2)

Innomed Knee Instruments surgical tools other useful

Universal plates have sharp spikes to help hold them in place. Lessens the chance of weakening the patella, as pre-drilling is not necessary. Four sizes available. Product Nos:4230-00 [Set of 4 Sizes] 4230-01 [Small 35mm x 31mm] 4230-02 [Medium 36mm x 32mm] 4230-03 [Large 37mm x 33mm] 4230-04 [Extra Large 38mm x 34mm] Instructions for Use Plate and Screw ImplantsAngular Stable X-Plate and 2-Hole Plate Cannulated Pediatric Osteotomy System (CAPOS) LCP Proximal Femoral Plate 4.5/5.0 LCP Proximal Radius Plates 2.4 Variable Angle LCP Mesh Plate 2.4/2.7 Variable Angle LCP Opening Wedge Plates 2.4/2.7

J-bone graft with double locking plate:a symphony of

Apr 15, 2020 · Atrophic distal femur non-union with bone defect (ADFNBD) has been a worldwide challenge to treat due to the associated biological and mechanical problems. The purpose of this study was to introduce a new solution involving the use of a J-shaped iliac crest bone graft (J-bone) combined with double-plate (DP) in the treatment of femoral non-union. LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plate shaft Combi-holes combine a dynamic compression unit (DCU) hole with a locking screw hole, providing the flexibility of axial compression and locking capability throughout the length of the plate. Straight plates available with 6 or 8 combi-holes in plate shaft. Curved plates available with 10, 12, 14, 16, 18, 20 or 22

NCB® Periprosthetic Femur Plate System Surgical

The NCB Periprosthetic Trochanter Plate is available in two different sizes (different width) whereas the height is the same. fixed-angle construct while using familiar plating techniques. The locking screw Femur Plate 95° Angled Distal Hole The most distal central plate hole is an- OrthoPediatricsProducts. Cannulated Screws. OrthoPediatrics cannulated screws are available in multiple lengths and thread patterns, making them ideally suited for pediatric applications when treating Slipped

OrthoPediatrics

The Delta Plate, which is the newest addition to the system, meets the need for greater flexibility in screw placement and allows for maximum screw divergence throughout the plate. This product may not be available in all markets. Please consult your local OP representative for availability. Orthopedic Plates & Screws Orthopaedic Plates GPC Medicals bone plate solutions include complex contoured and flat plates for spine fixation, orthopedic fracture applications, humeral, ankle and finger plate systems. Customers can specify a variety of hole configurations for locking, self-locking and threaded features.

PERI-LOC Periarticular Locked Plating Lower Extremity

PERI-LOC* Periarticular Locked Plating Lower Extremity treats lower extremity fractures including:lateral distal femur, proximal femur, distal femur, proximal tibia, anterolateral distal tibia, medial distal tibia plate. Features of Proximal Femur Locked Plate. Available in 4,6,8,10 and 13 hole PERI-LOC Periarticular Locked Plating System for Upper and PERI-LOC Periarticular Locked Upper and Lower Extremity Plates includes: Anatomically contoured locking plates Unique locking screw hole Fracture-specific plating options Radiolucent targeting systems (lower extremity) Large Fragment Plate Options. 4.5mm Proximal Humerus Locking Plate 4.5mm Lateral Distal Femur Locking Plate

PediLoc® Femur Locking Plate System - OrthoPediatrics

PediLoc femur plates are available in both distally contoured and anterior to posterior bowed options in sizes ranging from 3.5mm (10-18 holes) and 4.5mm (12-20 holes). This allows surgeons to appropriately address multiple indications in patients with varying skeletal maturity levels by utilizing a plate that accurately fits the femur. Periprosthetic Surgical TechniqueGuide into the plate hole perpendicular to the plate surface, and then tilt it as necessary to achieve the desired screw angle. For maximum stiffness reduction, screws should be placed as perpendicular to the plate as possible. Avoid angling the drill in the axial direction to ensure perpendicular screw placement in the plate (Fig. 14). Fig. 12

Plate and Screw Systems Instruments JAN 2 5 2013 &

with osteopenic bone. The PERI-LOC Proximal Femur Locking Bone Plates, Bone Screws, Locking Hole Inserts and Cable Accessories are indicated for:* fractures of the trochanteric region including simple intertrochanteric, reverse oblique trochanteric, transverse trochanteric, complex multi-fragmentary, and fractures with the medial, cortex Proximal Femur Locking Plate - Response OrthoThe Proximal Femur Locking Plate System is developed for repairing multifragmenty fractures, nonunions and malunions, periprosthetic fractures, fractures in normal or osteopenic bone and osteotomies of proximal femur. The design of the plates and unique instruments provide the comfortable operation conditions and create a fit that no additional bending and are helpful for

Surgical Technique - Smith & Nephew

Position the PERI-LOC 4.5mm Locking Proximal Femur Plate against the lateral aspect of the greater trochanter. Extending distally, the plate will line up along the lateral cortex of the femoral shaft. Thread a 3.2mm Drill Guide into the designated Alpha hole on the plate*. The 4.5mm Proximal Femur Locking Plate Taperloc Complete Hip System - Zimmer Biometfemoral head. Access the femoral canal with the straight box or offset chisel to determine the orientation of the femoral canal and access the lateral section of the proximal femur. This helps to clear the femoral canal postero-laterally to accept the starter reamer without interference from the

Targeter System for 4.5mm Distal Femur Locking Plate

Plate Selection Using the PERI-LOC 4.5mm Distal Femur Locking Plate Preoperative Template, determine the appropriate length plate for the fracture. In general, a longer plate allows for better mechanical advantage over a shorter plate. It is recommended that when selecting plate length, allow for five screw holes above the most proximal Treatment of Complex Proximal Femoral Fractures With the Aug 30, 2007 · Figure 1:The locking compression plate for the proximal femur is a precontoured, angular, stable, large-fragment plate (4.5/5.0/7.3 mm) available for

Zimmer® Periarticular Locking Plate System Brochure

contoured periarticular plates with locking screw technology. The unique plate designs feature a transitioned profile that is thinner in the metaphyseal and thicker in the diaphyseal areas. Locking screw holes are combined with compression slots, so that the plates can be used both as locking devices and for fracture compression. Zimmer® Periarticular Proximal Tibial Locking Plate into the plate hole, locking the screw into the plate. This technical innovation provides the ability to create a fixed-angle construct while using familiar plating techniques. Locking Plate Technology By using locking screws in a bone plate, a fixed-angle construct is created. In osteopenic bone or fractures with multiple fragments, secure bone

All Products - China Implant manufacturer, Stapler, Plate

ium Femur Locking Plate with Available Combined or Multi-Angle Hole ium Distal Medial Humeral Loc Plate with Available Combined or Multi-Angle Hole FOB Price:US $1 / Piece. Min. Order:1 Piece. Contact Now. Quick View. ium Distal Lateral Humeral Loc Plate I with Available Combined or Multi-Angle Hole

Leave a Comment